Inspección Mayor – Generador GE 6A3
TFA para Mecanalisis S.A.
SCOPE OF WORK
- Condition assessment of generator active components.
- Stator winding cleaning.
- Dielectric test on stator and rotor windings.
- End winding support system and lashings inspection.
- Stator end winding bump test and experimental modal analysis.
- Stator wedge tightness check.
- Technical assistance during stator rewedge.
- Rotor borescope inspection.
- Technical assistance on final assembly.
Categoría
Análisis de condición, Major inspection, Mantenimiento mayor, TFA, Turbo generator
Etiquetas
condition assessment, Major Inspection, partial discharge, TFA, Turbo Generators